Industrial Water Heater Mold Temperature Controller OMT-910-W For Blow Film

Ask Latest Price
Video Channel
Place of Origin :Dongguan, China
Brand Name :ORSTE
Certification :CE, ISO, SGS
Model Number :OMT-910-W
MOQ :1 Set / Order
Price :USD 850 / SET
Packaging Details :Standard Export Packing
Delivery Time :7-15 days
Payment Terms :TT, LC, Paypal, West Union, Cash
Supply Ability :500-3000 Sets / Year
Color :White & Blue
Function :Heating & Temperature Maintaining
Application :Plastic Injection
Weight :70 Kg
Temperature Range :50-180 degrees centigrade
Voltage :Standard Industrial Voltage
Name :Mold Temperature Controller
Condition :Brand New
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Industrial Water Heater Mold Temperature Controller OMT-910-W For Blow Film

OMT-W Mold Temperature Controller Water Heater.pdf...

Mold Temperature Controller, Temperature Controller, Water Heater, Industrial Temperature Controller, Plastic Temperature Controller, Plastic Machine

NAMING PRINCIPLE of Water Temperature Control Unit

OMT – xxxx – xx

① ② ③

① Orste Mold Temperature Controller

② First Two Numbers: Heater Power (kw)

Last Two Numbers: Pump Power (*10-1HP)

③ Notes

HTW: Medium is Water with High temperature D: Dual-heating Zone

FEATURES of Water Temperature Control Unit

1. Equipped with the design of one week automatic start/stop timer, screen can be converted between Chinese and English.

2. P. I. D. multi-stage temperature control system can maintain a mold temperature with an accuracy of ±1oC.

3. Adopts high efficiency water cycle pump, which can meet the demands of temperature control for precise molds and mold loop with minor diameter to achieve precise temperature control and high efficiency heat exchange. Pump inside adopts stainless steel to avoid explosion.

4. Multiple safety devices including power reverse phase protection, pump overload protection, overheat protection and low level protection that can automatically detect abnormal performance and indicate this via visible alarm.

5. For standard OMT-W, the heating temperature can reach 120oC, while for OMT-HTW, it can reach 160oC.

6. Equipped with high pressure protection, safety pressure relieving, automatic water supplying and air exhausting.

7. For OMT-W, direct cooling is adopted, while for OMT-HTW, indirect cooling is adopted. Automatic water supplying device ensures fast heat exchange.

APPLICATION of Water Temperature Control Unit

OMT-W series water heaters are widely used in the production of plastic product. They are mainly applied to heat up the mold and maintain temperature, also they can be used in other similar fields. Through the principle of heat exchange, they can shorten the product mold cycle and improve production efficiency.

FUNCTIONAL SCHEME of Water Temperature Control Unit

Water enter into mold temp. controller through the filter, and then be heated to the required temp. of the mold. The high temp. water is conveyed to the mold to maintain its heat by pump, then the water returned from the mold is heated and pressured to the mold to continue the circulation, thus achieving the effect of temp. control.

PARAMETERS of Water Temperature Control Unit

Model

Max Temp. (℃)

Pipe Heater (kw)

Pump Power (kw)

Max. Pump Flow (L/Min)

Max. Pump Pressure (bar)

Heating Tank Number

Cooling Method

Cooling Water pipe (inch)

Circulating Water Pipe (inch)

Dimensions
(H*W*D) (mm)

Weight (kg)

OMT-605-W

120

6

0.375

42

2.5

1

Direct Cooling

1/2"

3/8"

580*260*650

34

OMT-610-W

6

0.75

42

1

730*300*660

36

OMT-610-WD

6*2

0.75*2

42*2

2

980*390*860

72

OMT-910-W

9

0.75

56

1

730*300*660

36

OMT-910-WD

9*2

0.75*2

56*2

2

980*390*860

72

OMT-1220-W

12

1.5

235

1

980*390*860

68

OMT-2430-W

24

2.2

315

2

980*390*860

75

OMT-3650-W

36

3.75

495

3

980*390*860

83

OMT-1010-HTW

160

10

0.75

78

1

Indirect Cooling

980*390*860

70

Machine Details of Water Temperature Control Unit

Matters Needing Attention

Electrical installation of the machine should be done by qualified electricians.

Connecting the clean water and cooling water pipe after the machine is installed in a appointing place, make sure the inlet and outlet water pipe is in good condition.

Before connecting to AC Power Source, turn power switch to OFF position. While AC power source is connected, make sure specifications and overload protection rating of the power switch are suitable and reliable. When the machine is under care or maintenance, turn off both power switch and automatic operation switch.

Inquiry Cart 0